Does heart-rate drift tell me my threshold has slipped?
In ~23 trained cyclists with repeat tests, a bigger heart-rate rise at a fixed power went with a bigger fall in VT1 power (r = −0.76) over 1-5 h. Lab steps; no cut-off tested.
Rothschild et al. asked whether the drift of heart rate, breathing frequency or ventilation at a fixed power tells how far the moderate-to-heavy boundary (the first ventilatory threshold, VT1) has fallen during a long ride.
They pooled four of their laboratory's studies, in which 51 trained cyclists had VT1 power measured fresh and after about 2.5 h of riding at 90% of VT1 (in one study every hour until task failure, up to 6 h), and at each test also recorded heart rate, breathing frequency and ventilation at the same fixed power.
In 48 riders with usable data (85 change scores), a larger rise in heart rate at the fixed power went with a larger loss of VT1 power (repeated-measures r = −0.76, 95% CI −0.87 to −0.58), a larger rise in breathing frequency more weakly (−0.40) and ventilation not significantly (−0.25, P = 0.136).
A model of baseline VT1, VO2peak, breathing-frequency drift and heart-rate drift × time predicted the fatigued VT1 with a mean absolute error of 7.2 W in-sample and 8.3 W under bootstrap resampling; a simpler model using only baseline VT1 and heart-rate drift was nearly as good (8.7 W).
Across the cohort, heart rate at VT1 after 150-180 min was higher than fresh (147 vs 142 beats/min) while VT1 power had fallen.
Our reading: the first evidence that the heart-rate drift the base tracks moves with an actual loss of threshold power, within riders — but measured as a controlled fixed-power step, in riders the base already cites for the threshold slide (REF-179, REF-425, REF-181, REF-143), and with no cut-off.
Protocol
Key Results
| Measure | Result |
|---|---|
| Heart-rate drift vs change in VT1 power | rrm = −0.76 (95% CI −0.87 to −0.58), P < 0.001 |
| Breathing-frequency drift vs change in VT1 power | rrm = −0.40 (−0.64 to −0.09), P = 0.013 |
| Ventilation drift vs change in VT1 power | rrm = −0.25 (−0.52 to 0.08), P = 0.136 |
| Best model: baseline VT1 + breathing-frequency drift + heart-rate drift × time + VO2peak | MAE 7.2 W, R² 0.95 in-sample; 8.3 W (8.3-8.4), R² 0.93 bootstrap |
| Baseline VT1 + heart-rate drift + VO2peak | MAE 7.6 W in-sample, 8.4 W bootstrap; heart-rate coefficient −0.91 (−1.60 to −0.37) |
| Baseline VT1 + heart-rate drift | MAE 8.3 W in-sample, 8.7 W bootstrap; heart-rate coefficient −0.75 (−1.60 to −0.38), baseline VT1 coefficient 0.96 (0.89 to 1.00) |
| Heart rate at VT1, fresh vs after 150/180 min | 142 ± 11 vs 147 ± 10 beats/min (N = 58), P = 0.0002 |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
n = 51 recruited across four studies, 48 contributing 85 change scores; correlational and prediction modelling, validated only internally (bootstrap); not registered, no sample-size estimate; all four source studies are from the same laboratory and are already in the base; read from the full text (open access, CC BY 4.0)