Will two power meters agree?
Not always: 54 riders' own meters (9 makers, pre-2017) read 0.9% low on average against a physics reference, varied ±3.2% (SD) between meters, and 6 of 54 were off by more than 5%.
Maier et al. (Swiss Federal Institute of Sport, Magglingen) asked how true and how precise the mobile power meters that cyclists actually use are.
They calibrated 54 meters from 9 manufacturers belonging to 32 elite and recreational cyclists against a first-principles mathematical model of treadmill cycling: with the rider coasting downhill on a motorised treadmill, a back-pulling system was set to cancel the downhill force, then loaded 3 times with 4 different masses (the abstract's wording) while the rider pedalled to hold position, so the power needed is known from physics.
Trueness was the mean deviation from the model, precision the coefficient of variation. On average the meters read 0.9% low (−0.9 ± 3.2%, mean ± SD) and six deviated by more than ±5%; precision was high (CV 1.2 ± 0.9%) but differed between makers, with Stages varying more than SRM and PowerTap (both p < 0.001).
The authors conclude that power meters vary considerably in trueness and advise calibrating and adjusting every meter against a first-principles reference.
Our reading: the base's first fleet test of riders' own meters; most read within a few per cent, about one in nine was off by more than 5%, and the error is mostly a systematic per-meter deviation in trueness (a percentage of power, not the zero offset), not noise (precision) — so a meter is a consistent instrument for itself and a doubtful one for comparison with another meter.
Pre-2018 hardware; read from the abstract.
Protocol
Key Results
| Outcome | Result (abstract) |
|---|---|
| Trueness, all 54 meters | Mean deviation −0.9 ± 3.2% (mean ± SD); read as meters below the model, a sign convention the abstract does not define |
| Meters off by more than ±5% | 6 of 54 |
| Precision, all 54 meters | CV 1.2 ± 0.9% (mean ± SD) |
| Precision by manufacturer | Stages varied more than SRM (p < 0.001) and PowerTap (p < 0.001) |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
from the abstract; a fleet test of n = 54 power meters, which the rubric places at B as a validation study; held at B- because the criterion is a first-principles model of treadmill cycling, not a laboratory reference instrument, and because the abstract gives no power range, cadence, meter models or calibration routine (key methods missing)