Is my VO2max good for my age?
FRIEND ranks a lab VO2max among 22,379 healthy US adults' tests by decade, sex and mode (cycle runs lower than treadmill); each older decade's median is ~4 mL/kg/min lower. Not athletes; tables not read.
Kaminsky and colleagues updated the FRIEND reference standards for cardiorespiratory fitness in the United States. Thirty-four laboratories contributed 22,379 cardiopulmonary exercise tests (16,278 on a treadmill and 6,101 on a cycle ergometer) carried out between 1 January 1968 and 31 March 2021 in apparently healthy adults aged 20 to 89.
Percentiles of peak oxygen uptake were calculated for men and women for each decade of age and each mode, and again with maximal effort defined as a respiratory exchange ratio of at least 1.0 or at least 1.1.
The 50th percentile fell with age in both sexes and both modes, was higher in men at every age and higher on the treadmill than on the cycle; over six decades it fell on average 13.5% (4.0 mL/kg/min) per decade on the treadmill and 16.4% (4.3) per decade on the cycle. Mean peak VO2 was similar under either RER criterion across modes, ages and sexes.
The new treadmill standards are 1.5 to 4.6 mL/kg/min lower than the 2015 FRIEND standards, while the cycle standards are generally comparable to those of 2017. The authors conclude the update represents the US population better.
Our reading: the base's only VO2max norm, useful for "where does my lab VO2max sit for my age and sex", with three caveats an assistant must carry: it ranks people who were tested in US laboratories, not athletes; the decline per decade is cross-sectional, not anyone's rate of loss; and the actual percentile values were not read for this entry.
Protocol
Key Results
| Item (abstract) | Treadmill | Cycle ergometer |
|---|---|---|
| Tests | 16,278 | 6,101 |
| Average fall in the 50th percentile per decade, over six decades | 13.5% (4.0 mL/kg/min) | 16.4% (4.3 mL/kg/min) |
| Against the earlier FRIEND standards | 1.5-4.6 mL/kg/min lower than 2015 | generally comparable to 2017 |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
large cross-sectional measurement registry (the rubric's B+ for 100 or more), from the abstract (the article is open access on the publisher's site under CC BY-NC-ND, but that site refused a plain download, and no Europe PMC or repository copy exists). Not higher: a convenience registry of tests done in 34 laboratories over five decades, whose reasons for testing and protocols are not in the abstract; descriptive norms, not a test of anything