Is my critical power the same as my lactate steady state?
Close on average — CP ran 12 W higher in 10 small lab studies — but for one rider the 95% limits ran from about 19 W below to 44 W above. Treat them as different numbers.
Micheli and colleagues (Urbino, Verona, Western Ontario, Toronto, Groningen) asked how far apart critical power (CP) and the maximal lactate steady state (MLSS) sit, how well they agree for one person, and whether the answer depends on the variable used to express intensity.
They searched PubMed, Web of Science and Scopus to March 2023 and kept only within-subject studies in which participants rode (or ran) a constant-intensity trial at CP and at MLSS, so that oxygen uptake, heart rate and lactate at each boundary were measured rather than extrapolated from a ramp. Ten of 782 records qualified (11 samples, 111 participants, 19 women).
In power output, CP was higher than MLSS by 12.42 W on average (95% CI 4.69 to 20.16; prediction interval −11.62 to 36.47 W), with Bland-Altman limits of agreement of −19.23 to +44.08 W.
Expressed as oxygen uptake (0.09 L/min), heart rate (0.61 bpm) or blood lactate (1.63 mM), the differences were not significant, but those analyses held five, three and three studies, and three of the four studies with the largest power gaps reported no internal-load data.
In meta-regression the power gap grew with the mean CP (slope 0.21 W per W) and the mean MLSS (0.243 W per W) of the study samples. The authors conclude that CP exceeds MLSS in power output, more so in fitter riders, and that the wide individual spread means the two should not be used interchangeably; they attribute much of the gap to how each is measured.
Our reading: this is the first pooled estimate the base holds for the CP-MLSS gap, and it fits the base's two existing positions — MLSS sits somewhat below CP (REF-168) and threshold markers agree on the mean but not for the individual (REF-732).
Protocol
Key Results
| Intensity expressed as | Studies | Mean difference, CP minus MLSS (95% CI) | p | 95% limits of agreement | Heterogeneity |
|---|---|---|---|---|---|
| Power output | 10 samples | +12.42 W (4.69 to 20.16); prediction interval −11.62 to 36.47 W | 0.005 | −19.23 to +44.08 W (outer CI −30.91 to 55.76) | Q(9) = 96.490, τ = 10.065 W, p < 0.001 |
| Oxygen uptake | 5 studies (6 samples) | +0.09 L/min (−0.02 to 0.21) | 0.097 | −0.34 to +0.52 L/min | Q(5) = 15.238, τ = 0.090, p = 0.009 |
| Heart rate | 3 | +0.61 bpm (−7.70 to 8.91) | 0.784 | −15.84 to +17.05 bpm | Q(2) = 3.767, p = 0.152 |
| Blood lactate | 3 | +1.63 mM (−2.61 to 5.86) | 0.240 | −2.85 to +6.11 mM | Q(2) = 24.352, τ = 1.612, p < 0.001 |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
read from the full text (Europe PMC, CC BY 4.0). The rubric's A- line is an SR/MA "with serious heterogeneity or mostly small trials": 10 studies of 6 to 13 participants (n = 111), significant heterogeneity in the power-output analysis (Q(9) = 96.490, τ = 10.065 W), randomisation of trial order rated high or unclear risk in every study, and the heart-rate and lactate comparisons rest on three studies each. A measurement-agreement question, not a training outcome