Where does my first threshold sit against my threshold power?
In 14 well-trained men VT1 was 200 W against 255 W at MLSS (78%, our ratio), at 71-78% HRmax and RPE 11-12 (ramp; CIs of the mean, not one rider's band). One lab, men (B).
Pallarés and colleagues asked which capillary-lactate markers from a graded exercise test stand in for the ventilatory thresholds (VT1, VT2) and for the maximal lactate steady state (MLSS), and how well each repeats.
Fourteen well-trained male cyclists (VO2max 62.1 ± 4.6 mL/kg/min) did two identical graded tests (50 W start, +25 W per minute) and then 3-5 constant-load 30-min trials to find MLSS. Power at VT1 was 200 ± 36 W, at MLSS 255 ± 32 W and at VT2 304 ± 39 W; peak power was 388 ± 32 W.
The lactate threshold (LT, the highest workload before lactate rose above baseline, 214 ± 33 W) did not differ from VT1 (p = 0.147; bias −13.6 ± 34.3 W); LT + 0.5 mmol/L matched MLSS (p = 0.449; bias −4.5 ± 23.2 W); LT + 2.0 mmol/L and the 4-mmol/L point matched VT2.
VT1, VT2 and the lactate markers repeated well (CV 2.1-3.7%), DMAX, RER = 1 and V-slope less well (CV 5.0-10.3%). The authors give 95% CIs for heart rate and RPE at each event — VT1 at 71-78% of HRmax, 62-71% of heart-rate reserve and RPE 11-12 — and a zone scheme of their own in which the lowest training zone is 70-90% of VT1 power.
Our reading: for the question "where does easy end below threshold power", this is a clean group-mean anchor in trained men — VT1 sat about 55 W, or about a fifth, below MLSS (our arithmetic) — but the individual spread is wide (VT1 minus MLSS: −55.2 ± 30.3 W), so a fixed ratio misplaces some riders.
Protocol
Key Results
Power at each marker (mean ± SD), lactate at it, and its difference from VT1 and from MLSS (Table 1); test-retest CV (Table 2):
| Marker | Power (W) | Lactate (mmol/L) | Minus VT1 (W), p | Minus MLSS (W), p | Test-retest CV |
|---|---|---|---|---|---|
| VT1 | 200 ± 36 | 1.1 ± 0.4 | — | −55, p < 0.001 | 3.5% |
| LT (first rise above baseline) | 214 ± 33 | 1.6 ± 0.3 | +14, p = 0.147 | −41, p < 0.001 | 3.7% |
| V-slope | 235 ± 32 | 2.1 ± 0.6 | +35, p < 0.001 | −20, p = 0.006 | 5.0% |
| MLSS | 255 ± 32 | 4.5 ± 0.9 | +55, p < 0.001 | — | not repeated |
| DMAX | 257 ± 40 | 2.8 ± 1.4 | +57 | +2, p = 0.830 | 10.3% |
| RER = 1 | 259 ± 36 | 2.8 ± 1.3 | +59 | +4, p = 0.750 | 6.4% |
| LT + 0.5 mmol/L | 260 ± 36 | 2.1 ± 0.3 | +60 | +5, p = 0.449 | 3.7% |
| LT + 2.0 mmol/L | 300 ± 37 | 3.6 ± 0.3 | +100 | +45 | 3.4% |
| VT2 | 304 ± 39 | 4.2 ± 1.0 | +104, p < 0.001 | +49, p < 0.001 | 2.1% |
| OBLA 4 mmol/L | 304 ± 40 | 4.0 ± 0.0 | +104 | +49 | 3.7% |
| Peak power (VO2max test) | 388 ± 32 | — | — | — | 1.6% |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
a test validation study in one laboratory with n = 14 (the rubric's B for validation studies; single-lab, small n). Read from the full text (open access, CC BY 4.0)