The Reliability and Validity of the 3-min All-out Cycling Critical Power Test
Earlier work proposed estimating critical power (CP) from a single 3-min all-out cycling bout.
Here 12 participants each did a ramp test, three fixed-power trials from which CP and W′ were derived (1/time model), and four 3-min all-out tests, two with cadence held constant (isokinetic) and two against a fixed resistance (linear), yielding end power (EP) and work above end power (WEP).
Isokinetic EP did not differ from CP, linear EP did, and WEP differed from W′ under both modes. EP was very repeatable in both modes, WEP less so. The authors' verdict: the isokinetic test estimates CP reliably and validly, the linear test reliably but not validly, and W′ should not be estimated from the 3-min all-out test.
Participants
12 participants (abstract: "12 participants"); MEDLINE indexing lists male adults. Training status is not given in the abstract.
Protocol
Each participant completed 8 tests:
A ramp test.
2-4. CP and W′ from three fixed-power tests, fitted with the 1/time mathematical model.
5-8. EP and WEP from four 3-min all-out tests: 2 isokinetic (constant cadence) and 2 linear (fixed resistance).
Key Results
| Comparison | Result |
|---|---|
| EP-isokinetic vs CP | no significant difference (P=0.377) |
| EP-linear vs CP | significantly different (P=0.004) |
| WEP-isokinetic vs W′ | significantly different (P<0.001) |
| WEP-linear vs W′ | significantly different (P<0.001) |
Coefficient of variation between repeat tests: EP-isokinetic 1.93%, EP-linear 1.17%, WEP-isokinetic 8.44%, WEP-linear 5.39%.
Practical Application
Limitations
How this entry was checked and changed
test validation study, n=12