Is my watch's wrist heart rate accurate on the bike?
On average it was off by about 4.5 bpm cycling and 7 bpm lifting (probably low), but close at rest, in sleep and on the treadmill (44 studies). One session's error is not given.
Zhang and colleagues pooled studies that compared heart rate from wrist-worn optical (photoplethysmography) devices with a criterion of ECG or a chest strap. From five databases they included 44 articles with 738 effect sizes across 15 brands and analysed them with multilevel random-effects models by activity.
The mean difference was small during sleep (−0.40 bpm, 95% CI −1.64 to 0.83), at rest (−0.01, −0.02 to 0.00) and on the treadmill from walking to running (−0.51, −1.60 to 0.58), larger in cycling (−4.55, −7.24 to −1.87) and largest in resistance training (−7.26, −10.46 to −4.07), where the mean difference "increased by 3 bpm (2.5 to 3.5)" per 10 bpm rise in heart rate (whether the gap widened or narrowed is not stated).
The authors conclude that wrist devices show acceptable validity for most common activities. Our reading: on average a wrist sensor is close in steady, rhythmic or still conditions and reads low when the hands grip or the wrist flexes; the abstract reports group means only, so it says nothing about how far a single reading may stray — the number an athlete actually sees.
Protocol
Key Results
Mean difference of wrist optical heart rate from the criterion (bpm, 95% CI; from the abstract):
| Condition | Mean difference |
|---|---|
| Rest | −0.01 (−0.02 to 0.00) |
| Sleep | −0.40 (−1.64 to 0.83) |
| Treadmill, walking to running | −0.51 (−1.60 to 0.58) |
| Cycling | −4.55 (−7.24 to −1.87) |
| Resistance training | −7.26 (−10.46 to −4.07) |
| Resistance training, per 10 bpm higher heart rate | the mean difference "increased by 3 bpm (2.5 to 3.5)" |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
(from the abstract) — a systematic review and meta-analysis of 44 validation studies, held below the rubric's A- because the umbrella review in this batch rated it low quality on the Drucker tool (no registered protocol, no grey-literature search, precision and consistency not discussed; REF-1248, Table 2), and because heterogeneity, risk of bias, limits of agreement, participant numbers and funding are not in the abstract, the sign convention of the mean differences is not stated there, and validation studies of this kind test one device generation in a single session (no full text: not in Europe PMC, no open-access or repository copy listed by OpenAlex)