Can I trust the numbers on my watch?
Heart rate mostly (within about ±3%); resting HRV agreed with ECG mainly for Polar and chest-strap devices; VO2max, calories and sleep are rough estimates. Only 11% of devices validated.
Doherty and colleagues set out to keep a running ("living") summary of how accurately consumer wearables measure health outcomes, to be updated every six months.
A search on 5 June 2024 found 24 systematic reviews (8 with a meta-analysis, published 2013-2024) that compared consumer devices with an accepted reference; after removing overlap they held 249 validation studies of consumer devices (430,465 participants, 43% women). They ranked the reviews by risk of bias and took each outcome's numbers from the best available review.
Heart rate: a Fitbit meta-analysis found a mean bias of −3.39 bpm (more under-reading in cycling), and a narrative review of 29 studies found errors of about ±3% whatever the brand. HRV agreed closely with ECG at rest (ICC 0.98-1.00 for Polar; 0.85-0.99 across devices) and less during exercise or movement.
Watch VO2max came from the one VO2max review (REF-1253): bias +2.17 mL/kg/min with limits of agreement −13.07 to 17.41 for resting-based estimates, −0.09 with limits −9.92 to 9.74 for exercise-based ones.
Energy expenditure was under-read by about 3 kcal/min (limits of agreement −13 to 7 kcal/min, Fitbit), and the broadest review's authors were "hesitant to consider any device sufficiently accurate". SpO2 differed from a pulse oximeter by up to 2.0% (Apple Watch Series 6 only). Devices over-read total sleep and under-read wake after sleep onset.
Only 34 of 310 consumer devices released since 2003 had been validated for any outcome, and only 3.5% of the device-outcome pairs. The authors conclude that accuracy "remains inherently indeterminate" and that composite scores (readiness, stress, "body battery") have never been formally validated.
Our reading: the most useful map the base has of which wearable readings agree with a reference and which do not — a reading the sensor measures at rest agrees best, an algorithm's estimate worst — but its numbers are borrowed from reviews of very different quality, several are misreported in the abstract, and none describes a 2026 device.
Protocol
Key Results
| Outcome | Reviews (quality) and evidence | What the best available review found |
|---|---|---|
| Heart rate | 6 reviews (1 high, Fitbit only; 2 moderate; 3 low); 165 studies, 5816 participants | Fitbit meta-analysis of 52 studies: mean bias −3.39 bpm, more under-reading in cycling than in daily living, treadmill or overground walking; narrative review of 29 studies: errors of about ±3% regardless of device (Apple, Fitbit, Garmin) or criterion; Fitbit Charge 2: MAPE < 10% in 5 of 8 studies |
| HRV | 2 reviews (moderate, low), no meta-analysis; 22 studies, 714 participants | Polar devices at rest: ICC 0.98-1.00 ("near perfect validity"); a range of devices: ICC 0.85-0.99 at rest, falling to 0.85 with exercise or movement |
| Arrhythmia | 6 reviews (2 moderate, 4 low); 85 studies | Smartwatches (mostly Apple, Samsung) in 424,371 people: sensitivity 100% (95% CI 0.99-1.00), specificity 95% (0.93-0.97); mostly people already diagnosed |
| VO2max | 1 review (high); 14 studies, 403 participants | Resting-based: bias +2.17 mL/kg/min (95% CI 0.28-4.07), limits of agreement −13.07 to 17.41; exercise-based: bias −0.09 (−1.66 to 1.48), limits −9.92 to 9.74 |
| SpO2 | 1 review (low); 5 studies, 973 participants, Apple Watch Series 6 only | r 0.76-0.89 with pulse oximeters; mean absolute difference up to 2.0%; limits of agreement as wide as −5.8% to +5.9% in some studies |
| Steps | 8 reviews (1 high, Fitbit only; 3 moderate; 4 low); 184 studies, 6197 participants | Fitbit −3.11 steps/min (range −13 to 7); wrist devices mean −9% (median −2%); Fitbit Charge 2 MAPE 12% |
| Activity intensity | 4 reviews (1 moderate, 3 low), no meta-analysis; 126 studies, 4087 participants | Over 80% of Fitbit comparisons erred by more than 10% for light-to-vigorous time; moderate-to-vigorous minutes over-counted by up to 89.8 min/day; other devices MAPE 29-80% |
| Energy expenditure | 8 reviews (1 high, 4 moderate, 3 low; 3 meta-analyses); 218 studies, 7734 participants | Fitbit under-read about 3 kcal/min (limits of agreement −13 to 7 kcal/min) or −3%; 64-study meta-analysis across brands: effect size −0.23 (95% CI −0.44 to −0.03), primary-study error −21.27 to 14.76% |
| Sleep | 4 reviews (2 moderate, 2 low); 95 studies, 2985 participants | Total sleep over-read and wake after sleep onset under-read (mean absolute difference about 22.0 min/day, ICC 0.85, 4 studies); Fitbit over-read total sleep and sleep efficiency, often by more than 10% (3 studies); latency and wake errors 12-180% |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
an umbrella review, which the rubric places at A+, held at A-: the authors could pool nothing ("pervasive heterogeneity" in protocols, criteria, devices, firmware and outcomes; fewer than five comparable studies for any device and outcome), only 2 of the 24 reviews were rated high quality and 12 low, each headline number is one included review's number (the SpO2 figure comes from one low-quality review of a single watch), and the primary studies are small single-device validations, most recent August 2022. Read from the full text (open access, CC BY 4.0); the supplementary device tables were not read