How accurate is my watch's sleep time?
On average wrist trackers read about 17 min more sleep than a lab sleep test and missed some wake (24 studies). Useful for general patterns; one night's number can be far off.
Lee and colleagues pooled studies that compared sleep measured by consumer wrist-worn devices with polysomnography on the same night. Searches of seven databases (to March 2024) yielded 24 studies with 798 participants, most of them healthy adults, using Fitbit, Garmin, Jawbone, WHOOP, Apple Watch, Xiaomi, Huami, myCadian, Basis, Zulu, Empatica E4 and Fatigue Science devices.
Random-effects meta-analyses found significant mean differences between devices and polysomnography for total sleep time (−16.854 min, 95% CI −26.332 to −7.375; I² 67.5%), sleep efficiency (−4.691 points; I² 84.1%), sleep latency (2.574 min; I² 57.9%) and wake after sleep onset (13.255 min; I² 67.4%).
After trim-and-fill for suspected publication bias, the latency and wake differences were no longer significant. In subgroups, Fitbit's wake after sleep onset and other devices' sleep latency did not differ from polysomnography.
The authors conclude that wrist trackers are not as reliable as polysomnography for total sleep time, efficiency and latency but remain useful for general sleep patterns. The paper never says whether a difference is polysomnography minus device or the reverse.
In the forest plot, a Fitbit Flex in "sensitive" mode (which scores more movement as wake than the normal mode) gives total sleep +86.3 min and wake −74.8 min, against −45.9 and +44.0 min in normal mode; that is only consistent with polysomnography minus device, so devices over-read total sleep by about 17 min and efficiency by about 4.7 points and under-read wake by about 13 min (our reading).
That matches REF-364 and REF-1248, but contradicts the authors' wording that Fitbit "reported longer sleep latency" and other devices "reported longer wake after sleep onset" than polysomnography.
Our reading: on average a wrist device flatters the night by a quarter of an hour, mostly by counting quiet wake as sleep; how far one night can be off is not pooled, and per-study averages alone ran from about −105 to +86 min.
Protocol
Key Results
| Outcome | Studies | Pooled mean difference (95% CI) | I² | Direction by our reading of the forest plot |
|---|---|---|---|---|
| Total sleep time | 22 | −16.854 min (−26.332 to −7.375), P < .001 | 67.5% | device reads more sleep |
| Sleep efficiency | 18 | −4.691 points (−7.079 to −2.302), P < .001 | 84.1% | device reads higher efficiency |
| Sleep latency | 18 | 2.574 min (0.606 to 4.542), P = .010; trim-and-fill 0.611 (−1.577 to 2.788) | 57.9% | device reads shorter latency |
| Wake after sleep onset | 20 | 13.255 min (4.522 to 21.988), P = .003; trim-and-fill 0.171 (−0.122 to 0.464) | 67.4% | device reads less wake |
Subgroups (mean differences, 95% CI):
| Subgroup | Total sleep time | Sleep efficiency | Sleep latency | Wake after sleep onset |
|---|---|---|---|---|
| Fitbit | −6.564 (−18.890 to 5.763) | −3.626 (−7.639 to 0.387) | 5.602 (2.105 to 9.098) | 0.533 (−12.517 to 13.583) |
| Other devices | −26.674 (−39.051 to −14.297) | −5.498 (−8.050 to −2.946) | −0.122 (−1.493 to 1.249) | 24.140 (15.735 to 32.545) |
| Healthy | −12.504 (−21.420 to −3.587) | −6.493 (−8.989 to −3.996) | 2.005 (−9.452 to 13.452) | 13.910 (3.036 to 24.782) |
| Unhealthy | −26.188 (−50.158 to −2.217) | −2.159 (−6.731 to 2.413) | 3.120 (−2.231 to 8.470) | 11.955 (−4.192 to 26.102) |
| After 2021 | −20.544 (−34.832; 6.255 as printed) | −5.830 (−9.502 to −2.158) | 1.782 (−0.452 to 4.016) | 14.929 (0.404 to 29.453) |
| Before 2020 | −13.174 (−25.443 to −0.905) | −3.744 (−7.057 to −0.431) | 3.406 (0.102 to 6.710) | 12.634 (2.798 to 22.469) |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
a meta-analysis of small single-night validation studies with substantial heterogeneity would sit at A-; held at B+ because the paper never states which way its mean differences run and its own text describes latency and wake after sleep onset in the direction opposite to its forest plot, several subgroup confidence intervals and p-values contradict each other, limits of agreement were not pooled, no protocol registration is mentioned, and all 24 studies were rated "good" on a scale built for observational studies. Read from the full text (PubMed Central repository copy, located through OpenAlex) and the forest-plot image