Is my running power reliable?
In 12 trained men, Stryd power had a test-retest CV of ≤4.3% and tracked VO2 best (r ≥ 0.91); Garmin, Polar and RunScribe running power repeated poorly. Pre-2020 devices; abstract only.
Cerezuela-Espejo et al. (University of Murcia, with the University of Castilla-La Mancha) asked how repeatable five commercial running-power technologies are and how well each one's power relates to oxygen uptake.
Twelve endurance-trained men ran three submaximal protocols, each manipulating speed, body weight or slope, on a treadmill indoors and on an athletics track outdoors, on two occasions, while power was recorded at the same time by StrydApp, StrydWatch, RunScribe, GarminRP and PolarV and oxygen uptake by a metabolic cart.
Repeatability was judged by the standard error of measurement, CV and ICC; validity by a linear regression between power and oxygen uptake with the standard error of the estimate (the abstract does not say which was the predictor).
Stryd was the most repeatable technology in every environment and condition (SEM ≤ 12.5 W, CV ≤ 4.3%, ICC ≥ 0.980) and had the strongest relation to oxygen uptake (r ≥ 0.911, SEE ≤ 7.3%); Polar, Garmin and RunScribe kept some relation to oxygen uptake but their low repeatability, in the authors' words, questions their suitability.
Our reading: one small study, read from its abstract, that ranks Stryd first among the devices of its time for repeatability; it does not say that any device's watts are correct, and the absolute watts of different brands were not shown to agree.
Protocol
Key Results
| Technology | Repeatability (abstract) | Relation to VO2 (abstract) |
|---|---|---|
| Stryd (StrydApp, StrydWatch) | Most repeatable in all environments and conditions: SEM ≤ 12.5 W, CV ≤ 4.3%, ICC ≥ 0.980 | Best: r ≥ 0.911, SEE ≤ 7.3% |
| Polar Vantage (PolarV) | "Low repeatability" | "A certain relationship" with VO2 |
| Garmin Running Power (GarminRP) | "Low repeatability" | "A certain relationship" with VO2 |
| RunScribe | "Low repeatability" | "A certain relationship" with VO2 |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
from the abstract; a test validation study, which the rubric places at B, with n = 12 men; held at B- because the methods are not available beyond the abstract (device generations, slopes, loads, the numbers for the four other technologies) and because "validity" is a correlation with oxygen uptake rather than agreement with a measured mechanical power