Am I a VO2max non-responder?
One block cannot show it: in 24 controlled trials most of the spread in VO2max change was measurement error, with no strong evidence of true between-person differences (A-, from the abstract).
Renwick, Gurd and colleagues ran what they call the first systematic review and meta-analysis of inter-individual differences in VO2max trainability that used only studies with a non-exercising comparator group.
They searched EMBASE, PubMed and SCOPUS (32,968 records) and included 24 studies of standardised, supervised aerobic training that reported absolute or relative VO2max, change scores for the exercise and the non-exercise groups, and the SD of change for every group.
From the SDs of change they calculated the SD of individual response (SDIR) — by its usual definition the square root of the exercise arm's variance of change minus the control arm's (REF-430), that is, the spread of true responses left once test error and within-person variation are removed.
Three findings: most of the variation in observed change scores after an intervention is measurement error; a single study is generally too small to estimate SDIR with useful accuracy; and pooling SDIR² across studies gave no strong evidence that it is positive.
The authors conclude that there is not strong evidence for inter-individual differences in VO2max trainability across single interventions, and that clinically relevant predictors of the VO2max response are therefore unlikely to be found.
Our reading: the wide range of change seen in single-arm programmes such as HERITAGE (REF-429) cannot by itself show "high" and "low" responders; one person's change after one block is mostly the group's mean change plus noise.
No strong evidence for a positive SDIR is not proof that it is zero, and the paper does not ask whether someone who did not improve would improve on a different dose or intensity.
Protocol
Key Results
| Question (abstract) | Result |
|---|---|
| Records screened → studies included | 32,968 → 24 |
| Where the variation in observed VO2max change scores comes from | the majority is measurement error |
| Can one study estimate SDIR? | not with sufficient accuracy, because sample sizes are generally small |
| Pooled SDIR² across the 24 studies | no strong evidence for a positive value (estimate and interval not in the abstract) |
| Authors' conclusion | not strong evidence for inter-individual differences in VO2max trainability across single interventions; clinically relevant predictors of the VO2max response unlikely to be discovered |
| SD of change in the exercise arms vs the control arms | not in the abstract |
| Mean VO2max gain | not in the abstract |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
a meta-analysis restricted to controlled studies, which is the design a responder question needs, held below A because the authors describe the included studies as generally small and the pooled SDIR, its interval, the participant total and the heterogeneity are not in the abstract; read from the abstract (closed access; an accepted manuscript listed by OpenAlex in the Robert Gordon University repository sits behind a bot-check page and could not be read)