How big must a test gain be to be real?
Lab power tests' typical error ~0.9-2.0% (threshold power ~1.5%), 1.3× more in non-athletes; a 2nd test runs ~1.2% better from practice. One 1-2% gain can be noise (B+, from the abstract).
Hopkins, Schabort and Hawley pooled the reliability of power (or work) in physical performance tests from 101 studies of healthy adults. Reliability was measured as the typical (standard) error of measurement expressed as a coefficient of variation (CV), and as the percent change in the mean between trials.
For a given exercise duration the most reliable measures were field tests of sprint running (CV about 0.9%), peak power in an incremental test on a treadmill or cycle ergometer (about 0.9%), equivalent mean power in a constant-power test lasting 1 minute to 3 hours on a treadmill or cycle ergometer (0.9 to 2.0%), lactate-threshold power (about 1.5%) and jump height or distance (about 2.0%); mean power on isokinetic ergometers was relatively unreliable (CV above 4%).
CVs were larger for non-athletes than athletes (1.3×), for female than male non-athletes (1.4×), for very short (about 1 s) and long (about 1 h) tests than for 1-min tests (up to 1.6×), and for respiratory- than ergometer-based measures of power (1.4 to 1.6×); the time between trials had no clear-cut effect.
In studies with more than two trials, the CV between the first two trials was 1.3 times that between later trials, and performance improved by 1.2% between the first two trials but by only 0.2% between later ones.
Our reading: on a good laboratory test a single retest that moves 1-2% is inside the noise; the second test of a series looks about 1% better from practice alone; and a "plateau" can only be judged against a band at least this wide.
Protocol
Key Results
| Measure (abstract) | Typical error (CV) |
|---|---|
| Field test of sprint running | ~0.9% |
| Peak power, incremental test on a treadmill or cycle ergometer | ~0.9% |
| Equivalent mean power, constant-power test of 1 min to 3 h (treadmill or cycle) | 0.9 to 2.0% |
| Lactate-threshold power | ~1.5% |
| Jump height or distance | ~2.0% |
| Mean power, isokinetic ergometer | > 4% |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
pooled measurement data from 101 studies (a single reliability study sits at B in the rubric; pooling earns a step), held there because the search method is not described in the abstract, the protocols are laboratory and field tests up to 2001, and the number of studies behind each figure and the heterogeneity are not given; pre-2010, kept because it is still the base's only pooled estimate of endurance and power performance-test noise (REF-1166 pools isometric mid-thigh pull reliability). Read from the abstract (closed access; no Europe PMC copy, and the Victoria University repository record listed by OpenAlex is not open access and its host did not respond)