Is an elliptical or stepper as good a workout as running?
In 18 trained runners VO2max was similar on all three, and at the same share of each device's peak, heart rate and oxygen uptake did not differ. Acute; healthy. Abstract.
Bosch and colleagues (University of Cape Town, Stellenbosch University) noted that elliptical trainers and steppers are proposed for rehabilitating injured runners because they stress muscles and joints less than running, and compared the physiological responses to submaximal treadmill running with exercise on the two devices at the same relative workloads.
Eighteen trained runners (9 men, 9 women; 23 ± 3 years) completed randomised maximal oxygen uptake tests on all three devices, then 3-min submaximal stages at 60%, 70% and 80% of the peak workload established for each device, with breath-by-breath oxygen uptake, heart rate, fuel use and energy expenditure.
VO2max did not differ between treadmill, elliptical and stepper (49.3 ± 5.3, 48.0 ± 6.6 and 46.7 ± 6.2 mL/kg/min). Oxygen uptake, heart rate and carbohydrate and fat oxidation rose with intensity but did not differ between devices.
The authors conclude that the elliptical trainer and stepper are suitable substitutes for running when running load must be reduced, such as in rehabilitation from running injury.
Our reading: the base's only elliptical entry so far was recovery in the week after a marathon (REF-761); this one shows that, set by their own peak, both devices give a running-like cardiorespiratory stimulus with running-like heart rates. It is acute physiology in healthy runners — no training, no injured runners, no measure of joint or tendon load.
An earlier study outside the base (Turner 2010) found a lower VO2max and HRmax on an elliptical than on a treadmill, so the device and the user's skill on it may matter.
Protocol
Key Results
| Measure | Treadmill | Elliptical | Stepper |
|---|---|---|---|
| VO2max (mL/kg/min) | 49.3 ± 5.3 | 48.0 ± 6.6 | 46.7 ± 6.2 |
| VO2, heart rate, carbohydrate and fat oxidation at 60, 70 and 80% of device peak | differed between intensities | no difference between devices | no difference between devices |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
(from the abstract) — a within-subject comparison of 18 (the rubric's B+ band for crossovers of 15 or more) held at B, as REF-1430 was: PubMed indexes it as an observational cross-sectional study, the between-device result the base uses (heart rate) is a null reported without values or confidence intervals, the stages lasted 3 min, and there is no training outcome