Does heated tobacco spare a cigarette's CO?
COHb was lower after switching in 9 trials, all tobacco-funded: about half lower overall, about a fifth with 4+ weeks' follow-up (our back-calculation). A marker; no exercise tested.
Tattan-Birch and colleagues reviewed heated tobacco products for cessation, safety and smoking prevalence, for the Cochrane Tobacco Addiction Group. Thirteen completed studies were included: 11 RCTs in 2,666 people, median follow-up 13 weeks, and two time-series studies. All RCTs were funded by tobacco companies; eight were judged at unclear and three at high risk of bias.
No study reported smoking cessation. Against continued smoking, COHb was lower with heated tobacco (log mean difference −0.74; 9 studies, 1,807 people; I² 96%; moderate certainty, limited by risk of bias) and every study pointed the same way, though the sensitivity table shows −0.24 in the six trials with at least 4 weeks' follow-up.
Exhaled CO was 9.13 ppm lower (3 studies, 1,322; I² 4%). Against attempted abstinence, COHb was higher in intention-to-treat analyses (+0.69; 3 RCTs, 212) and not different per protocol (−0.32; 2 RCTs, 170), very low certainty. Adverse event comparisons were inconclusive.
Authors' declared interests: no tobacco or e-cigarette funding; two authors declare funding from makers of smoking cessation medication (Pfizer, Johnson & Johnson). Our reading: for the session question, "less carbon monoxide than cigarettes" stands, from industry-funded trials; "as low as not using" is not settled; and the review says nothing about exercise.
Protocol
Key Results
| COHb, heated tobacco vs continued smoking | n (studies) | LMD (95% CI) | I² |
|---|---|---|---|
| All data | 1807 (9) | −0.74 (−0.97 to −0.52; abstract and summary table print −0.92) | 96% |
| No high risk of bias | 1611 (7) | −0.76 (−1.07 to −0.44) | 97% |
| Only electronic devices | 1659 (7) | −0.84 (−1.07 to −0.60) | 96% |
| At least 4 weeks' follow-up | 1511 (6) | −0.24 (−0.36 to −0.12) | 95% |
Mechanisms
Practical Application
Limitations
How this entry was checked and changed
a systematic review of RCTs (rubric A) held one step down: I² 96% on COHb, eight RCTs at unclear and three at high risk of bias, all RCTs industry-funded, and the outcome is a biomarker, not performance or health