REF-1797 · Keefe et al., 2026 · Journal of Applied Physiology · Paper · PubMed

Male and female highly trained runners adapted comparably to seven 60-min heat-acclimation runs at a fixed easy pace (40 °C): no significant sex difference in how fast or how far core temperature, heart rate and sweat rate changed, in a randomised crossover of 18 runners (8 M / 10 F); heat gave larger falls in core temperature and heart rate and a larger rise in sweat rate than the same runs at 22 °C, and plasma volume changed in neither

Main caveat: 18 runners (8 M / 10 F) read from the abstract only; a null sex interaction in groups this size cannot exclude a small difference.
limited, mixed evidenceMeasured on trained to highly trained athletesRead from the abstract only

Keefe and colleagues asked whether the course and size of heat adaptation differ between male and female highly trained endurance runners, and how heat acclimation compares with the same training in temperate air.

Eighteen runners (8 men, 10 women) each completed two blocks of seven sessions in a randomised, counterbalanced order: one at 40 °C and one at 22 °C, both at 35% humidity, each session 60 min of running at 50% of the velocity at VO2max. Adaptation was the change from the first session in core temperature, skin temperature, heart rate, whole-body sweat rate and plasma volume.

There was no intervention × sex × session interaction for core temperature, heart rate or sweat rate, and no sex difference in the overall size of any heat adaptation. The heat block lowered mean and peak core temperature and baseline, mean and peak heart rate more, and raised sweat rate more, than the temperate block; plasma volume did not change after either.

The authors conclude that men and women adapt comparably to this protocol, and that temperate training gives part of the adaptation while heat adds to its size without changing its course by sex.

Participants

n = 18 highly trained endurance runners: 8 men, 10 women.
Age, VO2max, training volume, competition level, heat-acclimatisation status, menstrual phase and contraceptive use: not in the abstract.

Protocol

Two interventions per runner, randomised and counterbalanced: HEAT (40 °C, 35% RH) and TEMP (22 °C, 35% RH), seven sessions each.
Each session: 60 min running at 50% of the velocity at VO2max (controlled work rate, the same in both conditions).
Outcomes: change from session 1 in core temperature, skin temperature, heart rate, whole-body sweat rate and plasma volume.
Not in the abstract: session spacing, washout between interventions, how core temperature was measured, any heat stress test after the block, and the statistical values.

Key Results

QuestionResult
Did the course of adaptation differ by sex or intervention?No intervention × sex × session interaction for core temperature, heart rate or sweat rate (p > 0.05)
Did the size of heat adaptation differ by sex?No sex difference for any HEAT outcome
HEAT vs TEMP, mean and peak core temperatureLarger reductions with HEAT (main effect of intervention, p < 0.05)
HEAT vs TEMP, baseline, mean and peak heart rateLarger reductions with HEAT (p < 0.05)
HEAT vs TEMP, whole-body sweat rateLarger increase with HEAT (p < 0.05)
Plasma volumeNo change after either intervention
Temperate training alonePartial adaptation, by the authors' reading (sizes not in the abstract)
No effect sizes, confidence intervals or adaptation magnitudes are given in the abstract.

Practical Application

Sex is no reason to dose or judge a heat block differently in highly trained runners, on this protocol. Seven 60-min fixed-pace runs at 40 °C changed core temperature, heart rate and sweat rate alike in the 8 men and 10 women, both in course and in size; with 8 and 10 per sex, a small difference cannot be ruled out.
Where it meets [SYNTH-22]: the guide's third step asks whether sex explains a disagreement between entries.This trial gives a direct within-study test for heat acclimation and found no sex difference, so when two heat-acclimation entries disagree and one sample was mostly men, sex alone is not a likely explanation on this evidence; protocol, environment and training level remain candidates.It agrees with SYNTH-37, which holds that sex differences in thermoregulation are smaller than commonly claimed.
Where it meets [SYNTH-04]: heat beat matched temperate training for core temperature, heart rate and sweat rate, which agrees with the guide's thermoregulatory row.It differs on plasma volume: the guide lists plasma volume as a target of exercise in the heat (+6.5% after 10 days in REF-001; pooled +5.6% in REF-3491), but plasma volume was not reported to change after either block here (no values in the abstract).Inference: this does not reach the guide's dose lever, whose pooled data tie plasma volume to longer sessions rather than more of them (REF-3491); these were seven 60-min sessions at a controlled easy pace, not sessions held at a target core temperature.
Inference, not tested here: temperate training alone produced part of the adaptation, so an easy-paced heat block judged by heart rate should be compared against normal training, not against nothing, as the guide's heart-rate check already notes for REF-1667.
Not from this paper: performance in the heat, controlled-hyperthermia or humid protocols, longer blocks, and whether menstrual phase or hormonal contraception changes adaptation.

Limitations

18 runners (8 M / 10 F) read from the abstract only; a null sex interaction in groups this size cannot exclude a small difference.
Outcomes are adaptation markers; no time trial, time to exhaustion or other performance test is reported.
A controlled work rate protocol at 50% of vVO2max at 40 °C and 35% RH; results may differ with controlled-hyperthermia dosing, higher intensity or more humid heat.
Not in the abstract: washout length between the two blocks (carry-over of heat adaptation is possible in a crossover), menstrual phase and contraceptive control, age and fitness, how core temperature was measured, effect sizes, and funding or conflicts.
How this entry was checked and changed
Why this level

a crossover of 18 (the rubric's B+ band for crossovers) taken one step down because every outcome is a physiological adaptation marker (core and skin temperature, heart rate, sweat rate, plasma volume) with no performance test, and held at B- as a small study read only from its abstract