The 3-min all-out cycling test repeats well but does not give one rider's critical power or W′: across 20 small studies (284 participants), end-test power was reliable within three weeks (ICC 0.89-0.99) yet sat above critical power (pooled individual data: mean +11.7 W, 95% limits −37.1 to +60.5 W; random-effects gz 0.408, 95% CI 0.196-0.620), and work above end-test power agreed poorly with W′ (r = 0.499; limits −14.1 to +8.0 kJ). The authors advise isokinetic testing at 100 rpm or more after a full familiarisation and treating both numbers as their own measures. Read in full
Quittmann and Piehl (German Sport University Cologne) collected every study that tested the reliability or the validity of the 3-min all-out cycling test, in which the mean power of the last 30 s (end-test power, EP) is meant to estimate critical power (CP) and the work done above it (WEP) to estimate W′.
They searched two databases from 2006 to June 2025 and included 20 studies with 284 participants, mostly on a Lode Excalibur Sport ergometer in linear mode. Repeat tests within three weeks agreed well: intraclass correlations of 0.89-0.99 for EP and 0.76-0.98 for WEP. Validity was another matter.
Pooling individual data from studies that measured both, EP correlated very closely with CP (r = 0.993) but sat 11.7 W above it on average, with 95% limits from 37.1 W below to 60.5 W above, and the random-effects meta-analysis confirmed a systematic overestimate (gz 0.408) whose prediction interval stayed above zero.
WEP correlated only moderately with W′ (r = 0.499) and tended to underestimate it, with a prediction interval that crossed zero.
The authors find that test mode and cadence, familiarisation and encouragement move the results, advise against using the test to set an individual's CP or W′, and recommend isokinetic mode at 100 rpm or higher after a full familiarisation, with strong encouragement and no elapsed-time feedback. They treat EP and WEP as measures in their own right.
Participants
Protocol
Key Results
Reliability (test-retest within three weeks, 8 studies):
| Measure | Result |
|---|---|
| EP, ICC | 0.89-0.99 ('good' to 'excellent') |
| WEP, ICC | 0.76-0.98 |
| EP / WEP, Pearson r (3 studies) | 0.97-0.99 / 0.90-0.99 |
| Smart trainers, freely geared (53 riders) | EP CV 3.3%, WEP CV 17.9% |
| Lode, linear vs isokinetic (12 riders) | EP ICC 0.99 (CV 1.2%) vs 0.97 (CV 1.9%); WEP 0.98 (CV 5.4%) vs 0.94 (CV 8.4%) |
| Isokinetic 60 vs 100 rpm (14 riders) | EP ICC 0.91 (typical error 11.2 W) vs 0.95 (9.2 W); WEP 0.84 (1.8 kJ) vs 0.79 (1.3 kJ) |
Validity against CP and W′ from several time-to-exhaustion trials:
| Comparison | Result |
|---|---|
| EP vs CP, pooled individual data (N = 159) | r = 0.993, SEE 21 W; mean difference +11.7 W, 95% limits −37.1 to +60.5 W |
| WEP vs W′, pooled individual data | r = 0.499, SEE 5.4 kJ; mean difference −3.0 kJ, 95% limits −14.1 to +8.0 kJ |
| EP vs CP, random-effects (k = 15) | gz +0.408 (95% CI 0.196 to 0.620; prediction interval 0.024 to 0.792); fixed-effect 0.041 (0.003 to 0.079) |
| WEP vs W′, random-effects (k = 15) | gz −0.389 (95% CI −0.719 to −0.059; prediction interval −0.954 to 0.176); fixed-effect 0.048 (−0.047 to 0.143) |
| Chance a rider's EP exceeds CP / WEP exceeds W′ | 62.1 ± 18.5% / 35.6 ± 17.3% |
| R² across the 10 CP-validation studies | EP 27-98%; WEP 0.09-70.6% |
Practical Application
Limitations
How this entry was checked and changed
a systematic review of test validation studies whose quality appraisal and certainty we read in the full text; held at A- because the pooled data are small within-person measurement studies (most samples 6-21), certainty for validity carries high concerns (inconsistency, imprecision, possible publication bias), and several effects from one study were pooled as independent; no marker step, because end-test power and W′ are the measured subject of this validation (rule 3 exception)